product image
Battery Charger

Salient Features of Industrial Battery Charger In general the system confirms to IEC 146 and IS - 4540 standards Soft Start Battery path current limiting Automatic float cum boost change over Built in digitally controlled automatic regulation circuit Built in Auto Phase Reversal Operations Smoothing filter circuit to limit AC ripple. Charger overload protection Assisted with advanced battery monitoring (ABM) Day/Time selector switches for automatic charge/discharge cycle Insulation class for magnetics as per IS standards 7 tank processed powder coated painting shades Powder coated paints as per IS/RAl standards Controlled based advanced annunciation. Protection Overload Protection Back-up protection by MCCB's provided DCU/V and O/V protection Short circuit protection Battery input fuses Cubical lamp, voltmeters, control ckt, condenser protection by HRC fuses SCR, diode protection by semiconductor fuses Voltage Transient Protection by RC surge suppression networks Battery Reverse Current protection by charger blocked diodes Earth leakage protection by relay

6814772a5d263414004dd4a4 Card 2

product image
Numerical Servo Stabilizer

Salient Features No Wave form distortion. Low internal impedance. High Speed correction rate. Especially numerical Designed Voltage Sensing circuit. Output Independent of nature of load, Value of load Q power Factors. Under and over voltage cut. Alphabetical LCD display for displaying parameters & messages. Load on & Mains on indication. Inbuilt Phase sequence detector Alarm for fault occurrences. Protection against Over Voltage, Under Voltage, Overload Condition. Enhanced voltage Correction rate Controlled by micro controller. Settable required voltage within range of 380V-420V factory setting. Equipped with advance data logger for storage of fault history.

6814772a5d263414004dd4a4 Card 2

product image
Sinewave Inverter

SALIENT FEATURES Spike Protection - MOV (Metal oxide Varistor) spike suppressor mounted on the AC input damps any spike over 200% of nominal input voltage with transit response time of 25ns.(A standard surge voltage measures 40 micro sec. in width.) Battery Low Protection and Auto Restart - The invertor supplies when line power is not available. To avoid battery Damage from over discharge, the generator shuts down automatically. The unit automatically restarts when the AC line is normal. Overload /Short Circuit Protection - The inbuilt electronic sensing circuitry gets activated when the generator is on backup & overload or short circuit occurs. The Overload condition is latched till the mains resumes or is manually reset. The internal fuse protects the wall outlet from damage due to overload or short circuit when generator is on mains. Charger Trip Protections - If no Battery or dead battery is connected, generators will check for voltage at battery connectors. If it is less than specified voltage (i.e. 4 volts x no. of batteries) Charger will be Tripped to avoid over loading and charger trip light on front panel will glow. Charger - Sophisticated Constant Voltage current limit (CVCL) charger to avoid over charging is also provided. This also assures full charging within expected time, even when mains supply is very low (170V).This assures full backup. Designed to provide benefits: Pure sine wave technology One year on site comprehensive warranty including battery. Compact and aesthetic design. Child and shock proof features offering complete safety. Acid resistant body and battery cabinet optional.

6814772a5d263414004dd4a4 Card 2

product image
Transformers

IP ENCLOSURE PROTECTION FOR ISOLATION TRANSFOEMER: ARMO Isolation Transformer conforms to IP-30 protection as per IS:2147. DETAILS OF EARTHING FOR ISOLATION TRANSFORMER It is recommended that every Isolation Transformer should have its own grounded earth, complete in itself. CONSTRUCTIONAL FEATURES OF ISOLATION TRANSFORMERS Isolation Transformer shall invariably be in one air cooled section. The enclosures are constructed from MS angles and CRCA MS sheets of best quality of reputed make only. The professional painting process comprises of 7 Tank Pre-Treatment, Primer Coating and Two Coats of final finish paint or POWDER COATING.

6814772a5d263414004dd4a4 Card 2

product image
Frequency Relay

Low Burden Wide operating voltage range Wide frequency setting range 39. 00 to 70. 00 Hz Independently adjustable tripping stages. Consistent accuracy (± .03 Hz) Unaffected by voltage fluctuations Insensitive to harmonics & transient Built in timer(.1 to 99.9 Sec.) Built in event recorder for last three events. Under frequency & over frequency relay with 2 to 4 frequency stages. Adjustable under voltage blocking level. Field Adjustable relay rated frequency One operate time can give to each frequency stage. Protection stages can be separately blocked via internal blocking inputs. Application ARMO UFT frequency relays are used to monitor the frequency of an electrical system. Due to inadvertent splitting of inner connection in power system, isolated areas of the system may become deficient in the generation & frequency of the same may drop considerably giving rise to emergency conditions. In order to maintain control of system tinder this low frequency emergency some form of grated load shedding in needed. ARMO UFT relay is used to detect such condition & initiate load shedding to prevent complete system collapse.

6814772a5d263414004dd4a4 Card 2

product image
Frequency Relay

Silent Features Low burden Wide operating voltage range Wide frequency setting range 39.00 to 70.00 Hz Independently adjustable tripping stages two of which have a rate of change of frequency function. Consistent accuracy = +-0.03 Hz at 50 Hz Unaffected by voltage fluctuations Insensitive to harmonics & Transient Built in self-test mode Built in timer .02 to .18 sec ARMO-UFTR Frequency relays are used-to monitor the frequency of an electrical System. Due to inadvertent splitting of inner connection in power system. Isolated areas of the system may become deficient in the generation and frequency of the same may drop considerably giving rise to emergency conditions. In order to maintain control of system under this low frequency emergency,some form of graded load shedding is needed. ARMO-UFTR relay is used to detect such conditions and initiate load shedding to prevent complete system collapse. Type UFTR-41 consists of two/three definite time fully independent frequency measuring stage and one df/dt stage. Type UFTR-51 consists of two/three definite time fully independent frequency measuring stage and one df/dt stage. Separate Auxiliary relays are provided which get energized after the respective time delays (In case of df/dt the tripping frequency gradient). Tripping indications and reset push button are provided on the front of the relay. The relays are suitable for any application in industrial plants and to generators where definite time under over frequency protection with df/dt stage is required. Internal timers are provided for each operating circuits and separate aux relays ensure maximum flexibility of application. Two terminals are provided for the voltage input to the frequency sensing circuit. The measurement of the frequency is digital for which only the zero-crossing of the system voltage and not its amplitude, are of consequence. The relay is independent of the voltage fluctuations with a wide range. However the system voltage sink below a predetermined value in which the accurate measurement can no longer be expected the under voltage blocking circuit blocks all the outputs Technical Data AC voltage rating 110, 220VAC Auxiliary supplyvoltage From PT 66 to 135 V External 35 to 135 of PT Frequency setting range 39.0 to 60.0 Hz in step of 1 Hz Under frequency setting (dfdt) 1 Hz Sec to 9.9 H:: Sec at 50 Hz Operating voltage range 66 to 135 35-to 135 V The relay is blocked below & above this limit No. of tripped stageUFTR -51 UFTR-41 UFTR-6 I 4. Two of which have dfdt output One of which have dfdt output 4 No. of dfdt output Reference frequency 5 MHz Accuracy .03 Hz at 50 Hz Reset ratio 100% (Digital) Max reset time under &Overfrequency 50 ms Tripping delay for dfdt stage 5 cs to 9 cs unless stated set to 6 cs on delivery Evaluation period for delivery dfdt stages 26 52 mSunless stated set to 26 mS On Burden Aux Supply from PT 1.5VA Aux supply from an external source Aux DC /without tripping relays 1.5VA max at 150V 50Hz Contacts in relay 11 W for 4 stages Indicating signals 1 Pair of N/O reed contact 50VA max 2.5 Ad. C. Test voltage Low voltage inhibit LED LED tripping LED push button reset Reduced values are valid in case of repeat testing 2KV 50 Hz 1 min 5KV 1.2/50 usec Casting Does not apply to the terminal connected to a common Aux supply Guaranteed operation Ambient Flush mounting withrear connection 110 mmx 205mmx 250mm W H D temperature -5 – 55`C Silent Features Low burden Wide operating voltage range Wide frequency setting range 39.00 to 70.00 Hz Independently adjustable tripping stages two of which have a rate of change of frequency function. Consistent accuracy = +-0.03 Hz at 50 Hz Unaffected by voltage fluctuations Insensitive to harmonics & Transient Built in self-test mode Built in timer .02 to .18 sec.