SALIENT FEATURES
Spike Protection - MOV (Metal oxide Varistor) spike suppressor mounted on the AC input damps any spike over 200% of nominal input voltage with transit response time of 25ns.(A standard surge voltage measures 40 micro sec. in width.)
Battery Low Protection and Auto Restart - The invertor supplies when line power is not available. To avoid battery Damage from over discharge, the generator shuts down automatically. The unit automatically restarts when the AC line is normal.
Overload /Short Circuit Protection - The inbuilt electronic sensing circuitry gets activated when the generator is on backup & overload or short circuit occurs. The Overload condition is latched till the mains resumes or is manually reset. The internal fuse protects the wall outlet from damage due to overload or short circuit when generator is on mains.
Charger Trip Protections - If no Battery or dead battery is connected, generators will check for voltage at battery connectors. If it is less than specified voltage (i.e. 4 volts x no. of batteries) Charger will be Tripped to avoid over loading and charger trip light on front panel will glow.
Charger - Sophisticated Constant Voltage current limit (CVCL) charger to avoid over charging is also provided. This also assures full charging within expected time, even when mains supply is very low (170V).This assures full backup.
Designed to provide benefits:
Pure sine wave technology
One year on site comprehensive warranty including battery.
Compact and aesthetic design.
Child and shock proof features offering complete safety.
Acid resistant body and battery cabinet optional.
Silent Features
Low burden
Wide operating voltage range
Wide frequency setting range 39.00 to 70.00 Hz
Independently adjustable tripping stages two of which have a rate of change of frequency function.
Consistent accuracy = +-0.03 Hz at 50 Hz
Unaffected by voltage fluctuations
Insensitive to harmonics & Transient
Built in self-test mode
Built in timer .02 to .18 sec
ARMO-UFTR Frequency relays are used-to monitor the frequency of an electrical System. Due to inadvertent splitting of inner connection in power system. Isolated areas of the system may become deficient in the generation and frequency of the same may drop considerably giving rise to emergency conditions. In order to maintain control of system under this low frequency emergency,some form of graded load shedding is needed. ARMO-UFTR relay is used to detect such conditions and initiate load shedding to prevent complete system collapse.
Type UFTR-41 consists of two/three definite time fully independent frequency measuring stage and one df/dt stage.
Type UFTR-51 consists of two/three definite time fully independent frequency measuring stage and one df/dt stage.
Separate Auxiliary relays are provided which get energized after the respective time delays (In case of df/dt the tripping frequency gradient). Tripping indications and reset push button are provided on the front of the relay.
The relays are suitable for any application in industrial plants and to generators where definite time under over frequency protection with df/dt stage is required.
Internal timers are provided for each operating circuits and separate aux relays ensure maximum flexibility of application.
Two terminals are provided for the voltage input to the frequency sensing circuit. The measurement of the frequency is digital for which only the zero-crossing of the system voltage and not its amplitude, are of consequence. The relay is independent of the voltage fluctuations with a wide range. However the system voltage sink below a predetermined value in which the accurate measurement can no longer be expected the under voltage blocking circuit blocks all the outputs
Technical Data
AC voltage rating 110, 220VAC
Auxiliary supplyvoltage From PT 66 to 135 V External 35 to 135 of PT
Frequency setting range 39.0 to 60.0 Hz in step of 1 Hz
Under frequency setting (dfdt) 1 Hz Sec to 9.9 H:: Sec at 50 Hz
Operating voltage range
66 to 135
35-to 135 V
The relay is blocked below & above this limit
No. of tripped stageUFTR -51
UFTR-41
UFTR-6 I
4. Two of which have dfdt output
One of which have dfdt output
4 No. of dfdt output
Reference frequency 5 MHz
Accuracy .03 Hz at 50 Hz
Reset ratio 100% (Digital)
Max reset time under &Overfrequency 50 ms
Tripping delay for dfdt stage 5 cs to 9 cs unless stated set to 6 cs on delivery
Evaluation period for delivery dfdt stages 26 52 mSunless stated set to 26 mS On
Burden
Aux Supply from PT 1.5VA
Aux supply from an external source
Aux DC /without tripping relays
1.5VA max at 150V 50Hz
Contacts in relay
11 W for 4 stages
Indicating signals
1 Pair of N/O reed contact 50VA max
2.5 Ad. C.
Test voltage
Low voltage inhibit LED
LED tripping LED push button reset
Reduced values are valid in case of repeat testing
2KV 50 Hz 1 min
5KV 1.2/50 usec
Casting
Does not apply to the terminal connected
to a common Aux supply
Guaranteed operation Ambient
Flush mounting withrear connection
110 mmx 205mmx 250mm
W H D
temperature -5 – 55`C
Silent Features
Low burden
Wide operating voltage range
Wide frequency setting range 39.00 to 70.00 Hz
Independently adjustable tripping stages two of which have a rate of change of frequency function.
Consistent accuracy = +-0.03 Hz at 50 Hz
Unaffected by voltage fluctuations
Insensitive to harmonics & Transient
Built in self-test mode
Built in timer .02 to .18 sec.